Logic Control, Industrial/Machine Tool Relays, Protective Relays

GE Controls, North American Catalog, Logic Control, IEC Protective Relays

DINIL 03

Liquid Level Detector Relays

IEC Protective Relays, Liquid Level Detector Relays

Input Voltage:
With transformer

Contact Configuration:
1 selectable NO-NC contact

Number of Circuits:
1 and 2

Mounting Type:
DIN-Rail, Socket

SON

Liquid Level Detector Relays - Probes

IEC Protective Relays, Liquid Level Detector Relays

Description:
Cable union and probe encapsulated and protected by thermoplastic housing. Stainless steel probe

Cable Length:
5 m., 16.4' and 10 m., 32.8'

RDH

Differential Ground Fault Relays

IEC Protective Relays, Differential Ground Fault Relays

Reset Option:
Manual without test, Automatic with test

Contact Configuration:
One selectable NO-NC

Sensitivity Range:
0.2 - 1.2, 1-10

 


Liquid Level Detector Relays—Socket for Panel Fixing

IEC Protective Relays, Differential Ground Fault Relays

Description:
11 pin Socket for DINIL 02E and DINIL 03E for panel fixing. Front terminals

RDFF

Protective Relays

IEC Protective Relays, Control and Protection Relays

Function:
Integral protection (three-phase lines with transformer)
Unbalance and phase failure (three-phase lines with transformer)
Unbalance, phase failure and minimum voltage (three-phase lines with transformer)
Phase sequence and phase failure (three-phase lines with transformer)
Maximum and minimum voltage protection (three phase lines with transformer)
Maximum and minimum voltage protection (single phase lines with transformer)

Contact Configuration:
1 selectable NO-NC, 2 selectable NO-NC

Operating Range U min.:
5 - 20%, 0 - 20%

Operating Range U max.:
5 - 15%, 2 - 10%

RDT

Voltage Detection Relays

IEC Protective Relays, Control and Protection Relays

Contact Configuration:
1 selectable NO-NC, 2 selectable NO-NC

Operating Range:
0.1 - 1V, 0.5 - 5V, 3 - 30V, 12 - 125V, 40 - 400V

Input Impedance:
10 k ohms, 60 k ohms, 250 k ohms, 800 k ohms

Input Voltage:
40V, 60V, 75V, 110V, 300V, 600V

RDI

Current Detection Relays

IEC Protective Relays, Control and Protection Relays

Contact Configuration:
1 selectable NO-NC, 2 selectable NO-NC

Operating Range:
0.1 - 1A, 0.5 - 5A, 1 - 10A, 20 - 200mA, 20 - 200mV

Input Impedance:
10 k ohms, 60 k ohms, 250 k ohms, 800 k ohms

Input Voltage:
3A, 10A, 12A, 1A, 15V

RDIT

Current Detection Relays with Delay

IEC Protective Relays, Control and Protection Relays

Contact Configuration:
1 selectable NO-NC, 2 selectable NO-NC

Operating Range:
0.1 - 1V, 0.5 - 5V, 0.1 - 1A, 20 - 200mA, 20 - 200mV

Input Impedance:
0.033 ohms, 0.05 ohms, 2.2 ohms, 1 k ohms

Input Voltage:
12A, 10A, 3A, 1A, 15V

RCF-1

Frequency Control Relays

IEC Protective Relays, Control and Protection Relays

Contact Configuration:
1 selectable NO-NC, 2 selectable NO-NC

Jumper Terminals:
Without, Y1 - Y2, Y1 - Y3

Setting Range:
5 - 15Hz, 15 - 45Hz, 45 - 135Hz

RSR

Thermistor Relays (standard)

IEC Protective Relays, Control and Protection Relays

Contact Configuration:
1 selectable NO-NC

Temperature Range:
Standard

Thermal Probe Resistance Operating Range:
When Cold - 1.5 k ohms, When Hot - 2.5 k ohms

RSR

Thermistor Relays (adjustable)

IEC Protective Relays, Control and Protection Relays

Contact Configuration:
1 selectable NO-NC

Temperature Range:
Adjustable

Thermal Range with PT100 Probe:
30 - 60°C, 86 - 140°F
55 - 85°C, 131 - 185°F
80 - 110°C, 176 - 230°F
105 - 135°C, 221 - 275°F
130 - 180°C, 266 - 356°F